Wavelength selection for optical detection of high-temperature steam leaks in foggy environments
Objective This study investigates the challenges associated with detecting high-temperature steam leakage points in foggy environments.
Method Based on Mie theory, numerical simulations were performed to investigate the effects of the geometric standard deviation, water fog volume fraction, and optical path length on spectral transmittance. An experimental platform was also constructed in a laboratory environment to validate the simulation results.
Results The results indicate that the long-wave infrared band is the most suitable spectral region for the optical detection of high-temperature steam leakage points in foggy environments. The optimal wavelength range was determined to be 10 μm~12 μm.
Conclusion This study provides a theoretical basis for wavelength selection in high-temperature steam leakage point detection in special scenarios such as industrial production environments, confined spaces, enclosed spaces, and high-radiation environments.